Comet LWS 3525 S Triplex Pump – 2500 PSI, 24mm Solid Shaft, 1750 RPM
Comet LWS 3525 S professional triplex plunger pump for compatible pressure-washing, carpet-cleaning, truckmount and industrial cleaning systems. This heavy-duty pump features a brass manifold, ceramic plungers and a reversible 24 mm solid crankshaft for flexible right- or left-hand drive installation.
This pump is commonly researched as a replacement for HydraMaster 000-111-042 and several related Comet, Kärcher and OEM reference numbers. Because manufacturers may use different fittings, manifolds, shafts, pulleys and mounting configurations, always compare your existing pump before ordering.
Important fitment notice:
Match the complete pump model, shaft diameter, shaft orientation, inlet and outlet threads, mounting pattern, operating RPM and pressure rating. An OEM cross-reference number does not guarantee that every external fitting or installation component will transfer directly.
Performance Highlights
.jpg)
- Maximum pressure: 2,500 PSI
- Rated flow: Approximately 3.5 to 3.6 GPM, depending on the exact LWS 3525 S version
- Maximum pump speed: 1,750 RPM
- Shaft: 24 mm solid shaft
- Piston diameter: 18 mm
- Pump design: Positive-displacement triplex plunger pump
- Manifold: Brass
Professional Pump Construction
- Industrial ceramic plungers resist abrasion and operating heat
- Double-sealing Buna-textile V-packings support dependable pressure performance
- Forged bronze connecting rods provide long-term durability
- Hardened stainless-steel piston guides
- High-efficiency stainless-steel check valves
- Oversized ball bearings support demanding commercial operation
- Oil-bath crankcase provides continuous internal lubrication
- Finned, anodized aluminum crankcase helps control operating temperature
- Reversible crankshaft allows right-hand or left-hand drive installation where the equipment configuration permits
Specifications
| Manufacturer |
Comet Pumps |
| Pump series |
LWS |
| Model |
LWS 3525 S |
| Maximum pressure |
2,500 PSI |
| Rated flow |
Approximately 3.5–3.6 GPM, depending on exact factory version |
| Maximum speed |
1,750 RPM |
| Shaft diameter |
24 mm |
| Shaft style |
Solid shaft |
| Piston diameter |
18 mm |
| Inlet connection |
1/2-inch female threaded port; verify thread standard before installation |
| Outlet connection |
3/8-inch female threaded port; verify thread standard before installation |
| Oil capacity |
Approximately 11 fluid ounces |
| Approximate weight |
13.4 lb. |
| Motor, engine, clutch and pulley |
Not included unless specifically stated elsewhere in the offer |
Cross-Reference and Search Numbers
The following numbers may be associated with this pump family or prior equipment applications. Cross-reference information is provided to help identify the product and must be confirmed by physical comparison.
- Comet LWS 3525 S
- Comet 6301.1201.00
- Comet 6301120100
- Comet CP63011201
- HydraMaster 000-111-042
- HydraMaster HM-111042.EA
- Kärcher 8.702-574.0
- Kärcher 87025740
- GTIN 8054639160736
Possible Equipment Associations
This pump has been associated with certain configurations of HydraMaster equipment, including some:
- HydraMaster SpitFire truckmount systems
- HydraMaster Boxxer 421 truckmount systems
- HydraMaster Boxxer 318 truckmount systems
Application warning: Model names alone are not sufficient to confirm compatibility. Truckmount manufacturers may change pumps, shafts, fittings, mounting brackets and drive systems during a production run. Verify the pump installed in your machine.
What You Receive
- One Comet LWS 3525 S pump assembly
Not included unless expressly shown and stated: pulley, electric clutch, mounting bracket, unloader, regulator, pressure gauge, hoses, fittings, couplers, motor, engine or installation labor.
Before Ordering
- Locate the model and part number on your existing pump.
- Measure the crankshaft diameter and usable shaft length.
- Confirm whether the shaft must extend from the right or left side.
- Confirm the pump operates at no more than 1,750 RPM.
- Compare the mounting-hole pattern and crankcase dimensions.
- Verify the inlet and discharge thread types.
- Confirm that your motor or engine provides adequate horsepower.
- Determine whether your application requires standard or high-temperature seals.
Frequently Asked Questions
Does this pump include the motor or engine?
No. This listing is for the pump assembly unless another component is specifically identified as included.
Does it include the pulley or electric clutch?
No. Drive components are normally sold separately. The pulley or clutch must match the 24 mm pump shaft and the equipment’s required operating speed.
Can I operate the pump faster than 1,750 RPM to obtain more flow?
No. Do not exceed the manufacturer’s maximum pump speed. Excessive RPM can damage seals, valves, bearings, plungers and other internal parts.
Is this a direct replacement for HydraMaster 000-111-042?
It is commonly cross-referenced to that number, but installation details can vary. Compare the shaft, mounting pattern, ports, fittings, pulley alignment and operating specifications before ordering.
Can this pump handle hot water?
Temperature capability depends on the exact factory configuration and seal package. Do not assume that a standard LWS 3525 S includes the optional hot-water seal package. Confirm the supplied Comet part number when high-temperature operation is required.
Does the pump arrive ready to operate?
Inspect the pump and verify the crankcase oil level before startup. Proper inlet-water supply, alignment, belt tension, unloader adjustment and installation are required. Never operate the pump dry.
Installation and Operating Notes
- Installation should be performed by a qualified technician familiar with high-pressure pump systems.
- Flush debris from supply hoses and plumbing before connecting the new pump.
- Provide an unrestricted water supply with adequate flow.
- Never allow the pump to run without water.
- Do not exceed the rated pressure, RPM or temperature.
- Align pulleys carefully and avoid excessive belt tension.
- Use an appropriately sized unloader, regulator and pressure-relief system.
- Check the oil level before initial use and maintain the pump according to the Comet service schedule.
- Protect the pump from freezing. Freeze damage is not a manufacturing defect.
Final verification required:
Pumps that look similar can have different shafts, seals, port threads and operating specifications. Purchases are fulfilled according to the part number ordered. Review all specifications and compare the existing pump before placing the order.
Images are for identification and reference. Product appearance, labels and minor components may change without notice. Specifications and OEM associations should be verified before installation.
Pump Comet Lws3525S 3.5gpm @ 2500psi 1750rpm
Features
- 1/2″ FPT Inlet – 3/8″ FPT Outlet except where indicate
- High Quality Buna-Textile Double-Sealing V-Packings
- Reversible Crankshaft for Easy Right or Left Hand Mounting
- Solid or Hollow Shaft
- Forged Bronze Connecting Rods with Lifetime Warranty
- Die-Cast, Anodized Aluminum Crankshaft-Fin Design for Optimal Operating Temperature
- Hardened Stainless Steel Piston Guides
- Flange for Direct Mounting to Gas Engines or Electric Motors
- High Efficiency Stainless Steel Check Valves
- High Quality Oversized Ball Bearings
- Abrasion Proof, Heat Resistant, Industrial Ceramic Plungers
- Optimal Oil Bath for High Speed Operation
Specifications
|
Shaft Size (Diameter)
|
Ø 24mm
|
|
Shaft Style
|
Solid Shaft
|
| Piston Diameter |
18 mm |
|
RPMs
|
1750
|
| GPM |
3.5 |
| PSI |
2500 |
|
Inlet Connection
|
1/2" FBSP
|
|
Outlet Connection
|
3/8" FBSP
|
|
Pump Head
|
Brass or Stainless Steel
|
|
Oil Capacity
|
11 fl. oz.
|
|
Weight
|
13.4 lbs
|
|
Max Temperature
|
140° F
|
|
Warranty
|
5 Years
|
Compare to current or past OEM associations
LWS 3525 S
Lws3525S
6301.1201.00
CP63011201
HM-111042.EA
Hydramaster 000-111-042
6301.1203.00
8.702-574.0
87025740
8080546403062
Used on some Hydramaster Spitfire, Boxxer 421 and 318 Truckmounts.
Optional
|