Clean Storm 20211223, Stationary LP Gas Hot Water Pressure Washer 4 GPM 4000 PSI 10 HP 230V 1-Phase
Description
The Clean Storm 20211223 is a stationary industrial hot water pressure washer delivering 4 GPM at 4000 PSI, powered by a 10 HP 230V single-phase electric motor and an LP gas-fired forced-air burner. Built on a heavy-duty coated steel tubing skid frame, this system features an industrial triplex plunger pump with ceramic plungers, stainless steel valves, and a Schedule 80 heating coil wrapped in stainless steel that heats water up to 195° F. Engineered for continuous fixed-location wash bays, it includes a 50' x 3/8" high-pressure hose, dual wand with side handle valve, low-pressure chemical injection, and four quick-change nozzles for demanding commercial and industrial degreasing.
Features
- High-Output Triplex Plunger Pump: Equipped with durable ceramic plungers and corrosion-resistant stainless steel valves, protected by an unloader valve, mechanical thermal protection, and a secondary pressure relief pop-off valve.
- 10 HP Industrial Electric Motor: Totally enclosed motor operating on 230V, 40 Amp, single-phase power with integrated thermal overload protection for extended duty cycles.
- LP Gas Forced-Air Burner System: High-efficiency forced-air burner utilizes a heavy-duty Schedule 80 heating coil with a protective stainless steel wrap to achieve temperatures up to 195° F.
- Precision Temperature Controls: Regulated via an adjustable thermostat and an automatic high-temperature limit switch for safe, consistent thermal output.
- Low-Pressure Chemical Injection: Integrated downstream chemical injector allows controlled application of concentrated liquid detergents and degreasers.
- Industrial Coated Steel Skid Frame: Rigid 47" x 29" x 46" tubular steel frame coated for superior resistance against moisture, chemicals, and shop corrosion.
- Complete Spray Assembly Included: Comes ready with a heavy-duty trigger gun, dual wand with side handle valve for instant high-to-low pressure switching, 50' x 3/8" hose, and 0°, 15°, 25°, and 40° quick-connect nozzles.
Applications
- Commercial fleet maintenance bays, semi-truck wash stations, and municipal transit depots
- Heavy construction equipment, agricultural machinery, and earthmoving service centers
- Industrial manufacturing facilities, machine shops, and metal fabrication plants
- Food processing plants, commercial kitchens, and sanitation washdown areas (with proper exhaust venting)
- Oilfield equipment yards, marine shipyards, and mining maintenance facilities
Specifications
| Brand |
Clean Storm |
| Model / Part Number |
20211223 |
| Mounting Configuration |
Stationary Skid Frame |
| Water Output Type |
Hot Water (Up to 195° F) |
| Operating Pressure |
4000 PSI / 276 Bar |
| Flow Rate |
4.0 GPM / 15.2 LPM |
| Motor Horsepower |
10 HP (Totally Enclosed, Thermal Overload Protected) |
| Electrical Requirements |
230 Volt / 40 Amp / Single Phase (1-Phase) |
| Power Cord Length |
10 Feet |
| Pump Type & Protection |
Industrial Triplex Plunger Pump (Ceramic Plungers, Stainless Valves) / Mechanical Thermal Protection |
| Maximum Pump Inlet Water Temperature |
140° F |
| Burner Fuel Type |
L.P. Gas (Liquid Propane) — Requires 1" Gas Supply Line |
| Heating Coil Construction |
Schedule 80 Steel Coil with Stainless Steel Wrap |
| Burner Exhaust Stack Diameter |
8 Inches |
| Frame Material & Finish |
Industrial Coated Steel Tubing |
| High-Pressure Hose Dimensions |
50 Feet x 3/8 Inch (Standard 3/8" Quick-Connect / NPT Fittings) |
| Included Nozzles |
Quick-Change 0°, 15°, 25°, and 40° |
| Overall Dimensions (L x W x H) |
47" x 29" x 46" |
| Shipping Weight |
570 lbs |
Cross-Reference SKUs
| 20211223 |
| CS-20211223 |
| CS20211223 |
| CLEANSTORM-20211223 |
| CLEAN STORM 20211223 |
| 2021-1223 |
| CS-4000-4GPM-LP |
| CS-10HP-230V-1PH-LP |
Tips and Additional Information
Gas Line & Exhaust Venting: This stationary LP gas unit requires a dedicated 1" gas supply line to maintain proper BTU output and burner combustion. Because it burns fuel, it must be installed outdoors or indoors with an 8" exhaust stack vented to the exterior and adequate make-up air. Always consult a licensed HVAC and gas piping professional prior to installation.
Chemical Injector Placement: The factory-installed low-pressure chemical injector is calibrated for use with the included 50' x 3/8" hose. If you plumb this unit into a longer wash-bay pipeline or extended hose reel exceeding 50 feet, you must relocate the downstream chemical injector within 50 feet of the trigger gun to ensure proper Venturi suction.
Thread Sealing & Pre-Start Inspection: When connecting high-pressure 3/8" NPT fittings, hoses, or plumbed water/gas lines, apply high-temperature PTFE thread tape or industrial pipe sealant rated for gas/high-pressure service, leaving the first two threads bare to prevent sealant shreds from fouling the unloader valve or spray nozzles. Before initial startup, verify pump crankcase oil levels, confirm inlet water temperature does not exceed 140° F, and purge air from the water lines before igniting the burner.
Frequently Asked Questions
Q: Can this pressure washer be installed inside a wash bay or garage?
Yes, provided it is properly vented to the outdoors using the 8" burner exhaust stack and supplied with sufficient fresh make-up air for safe combustion. Consult a local HVAC professional to meet local mechanical and fuel-gas codes.
Q: What size gas line is required to run the LP gas burner?
This model requires a 1" LP gas supply line with properly regulated gas pressure to support its forced-air burner system at full thermal capacity.
Q: Why isn't my chemical injector drawing soap when I add an extra 50-foot hose?
Downstream low-pressure chemical injectors rely on a pressure differential that diminishes over long hose runs due to friction loss. For hose lengths or hard-piped bay lines longer than 50 feet, the injector must be relocated within 50 feet of the trigger gun.
Q: Can I feed hot water into the pump inlet to get even higher output temperatures?
No. The maximum inlet water temperature for the triplex plunger pump is 140° F. Exceeding 140° F at the pump inlet will damage the pump seals and ceramic plungers, even though the downstream heating coil outputs up to 195° F.
Warranty & Safety Information
Manufacturer Warranty Coverage: The Clean Storm 20211223 is backed by the manufacturer's limited industrial warranty covering defects in materials and workmanship across the steel skid frame, Schedule 80 heating coil, triplex plunger pump, and 10 HP electric motor under normal commercial service.
Conditions That Void Warranty & Critical Safety Warnings:
- Improper Venting & Gas Supply: Operating the LP gas burner indoors without an 8" exterior exhaust flue and certified make-up air creates a lethal carbon monoxide hazard and voids burner coverage.
- Exceeding Pressure or Temperature Limits: Tampering with the unloader valve or secondary pop-off valve to exceed 4000 PSI, supplying inlet water above 140° F, or bypassing the 195° F high-limit switch will void the warranty.
- Dry Running & Freezing: Running the triplex pump without an adequate water supply, failing to protect the coil and pump from freezing temperatures, or operating without proper pump oil voids pump and coil warranties.
- Electrical & High-Pressure Hazards: Connecting the motor to an improperly rated circuit (must be 230V, 40A, single-phase) or disconnecting hoses and quick-couplers while the system is pressurized risks severe injury and voids coverage.
|