Clean Storm 28095, 3-8 Inch MIP NPT Countersunk Hex Socket Plug Solid Brass Pipe Fitting Cap for Pressure Washers and Manifolds
Description
The Clean Storm 28095 3/8-inch MIP countersunk hex socket plug is a heavy-duty solid brass fitting engineered to securely seal unused threaded ports in high-pressure fluid, pneumatic, and plumbing systems. Featuring tapered 3/8-inch Male Iron Pipe (MIP/NPT) threads and an internal Allen hex drive, this low-profile plug sits flush against manifold and pump housings to eliminate snag hazards and protruding edges while delivering dependable leak resistance under demanding operating conditions.
Features
- Flush-Mount Countersunk Design: Internal hex socket head installs cleanly inside female ports for a sleek, snag-free profile on manifolds, pump heads, and tight equipment enclosures.
- Heavy-Duty Solid Brass Construction: Naturally resists rust, mineral buildup, and galvanic corrosion in continuous wet, chemical, and high-moisture pressure washing environments.
- Precision Tapered NPT/MIP Threads: Machined 3/8-inch male pipe threads wedge tightly into female ports to create a reliable mechanical seal for liquids, compressed air, and non-corrosive gases.
- Standard Internal Hex Drive: Installs and removes quickly with a standard Allen wrench, reducing the risk of rounding external flats in recessed or confined spaces.
- Multi-System Compatibility: Built to cap unused ports on high-pressure pump heads, chemical injectors, bypass valves, air compressors, and commercial plumbing manifolds.
Applications
- High-pressure washer pump heads, unloader valves, and bypass manifolds (including multi-port pump heads such as Pumptec 205V and 207V series)
- Truckmount carpet cleaning equipment, portable extractors, and commercial water-transfer manifolds
- Compressed air lines, pneumatic control blocks, and air receiver tank auxiliary ports
- Commercial and industrial plumbing networks, gauge ports, and fluid distribution headers
- Low-to-medium pressure hydraulic return lines and industrial machinery fluid housings
Specifications
| Brand |
Clean Storm |
| Part / Model Number |
28095 |
| Thread Size & Standard |
3/8" MIP / NPT (Male National Pipe Taper) |
| Fitting Style |
Countersunk Internal Hex Socket Plug |
| Body Material |
Solid Brass |
| Finish |
Natural Machined Brass |
| Drive Type |
Internal Allen / Hex Key |
| Swivel Mechanics |
Non-Swivel Rigid Threaded Fitting |
| Maximum Operating Pressure |
Up to 1,200 PSI (system dependent) |
| Operating Temperature Range |
-65°F to 250°F (-53°C to 121°C) |
| Compatible Media |
Water, Detergents, Compressed Air, Oil, Non-Corrosive Fluids |
Cross-Reference SKUs
| 28095 |
| 017108 |
| 17108 |
| 06115-06 |
| 0611506 |
| 109AL-6 |
| 109AL6 |
| 109CS-C |
| 109CSC |
| 118-6 |
| 1186 |
| 118-C |
| 118C |
| 219P-6 |
| 219P6 |
| 226600 |
| 23155X6 |
| 3153x6 |
| 50785K114 |
| 68592 |
| 88155 |
| BP118-6 |
| BP1186 |
| D415 |
| E23155-6 |
| E231556 |
| E23155X6 |
| S219P-6 |
| S219P6 |
Tips and Additional Information
Thread Sealing: Because 3/8" MIP/NPT threads are tapered, always apply high-density PTFE thread seal tape (wrapped 3 to 4 turns clockwise) or a compatible anaerobic pipe thread sealant before installation to prevent galling and ensure a leak-tight seal.
Proper Alignment: Start the plug by hand for the first two to three turns to verify smooth engagement and avoid cross-threading softer aluminum or brass pump manifolds. Once aligned, tighten firmly with a properly sized Allen hex key until snug; avoid over-torquing, which can crack cast female housings.
Non-Live Static Design: This is a rigid, non-swivel static plug intended solely for permanently or semi-permanently blanking off unused ports, not for rotational or live-swivel connections.
Pre-Install Inspection: Inspect both the male plug threads and the female receiving port for burrs, old sealant residue, or debris prior to assembly, and ensure the internal hex socket is clean so the Allen wrench seats fully without stripping.
Frequently Asked Questions
Q: Is 3/8" MIP the same thread size as 3/8" NPT?
Yes. MIP (Male Iron Pipe) and NPT (National Pipe Taper) share the exact same 3/8-inch nominal diameter and 18 threads-per-inch (TPI) tapered profile, making them directly interchangeable in standard North American plumbing, pneumatic, and pressure washer ports.
Q: Will this plug sit completely flush with my pump head or manifold surface?
Yes, the countersunk headless design allows the plug to thread cleanly into standard 3/8" FIP/NPT female ports so the top sits flush or slightly recessed, eliminating protruding hex heads in tight spaces.
Q: Can I use this brass plug on a Pumptec 6-port pump head?
Yes, the Clean Storm 28095 is commonly used to block off unused 3/8" auxiliary inlet or discharge ports on multi-port pump heads such as the Pumptec 205V and 207V series operating between 500 and 800 PSI.
Q: Should I use PTFE tape or liquid thread sealant with this fitting?
Either high-density PTFE tape or a non-hardening pipe thread sealant rated for your fluid and pressure range works well. Apply sealant starting one thread back from the tip so shreds or paste do not enter downstream valves or spray nozzles.
Warranty & Safety Information
Warranty Coverage: Backed by a standard manufacturer warranty against defects in materials and workmanship under normal commercial and industrial use. Warranty coverage is voided by improper installation, cross-threading, over-torquing, exposure to incompatible corrosive chemicals, or operation beyond rated pressure and temperature limits.
Pressure & Temperature Limits: Do not exceed 1,200 PSI maximum working pressure or temperatures outside -65°F to 250°F. Always verify the lowest-rated component in your assembly before pressurizing the system.
Safety Hazards: Relieve all fluid and air pressure completely and disconnect power sources before installing, tightening, or removing this plug. Never attempt to tighten a leaking fitting while the system is pressurized, as high-pressure fluid or compressed air ejection can cause severe bodily injury. Wear ANSI-approved eye protection during installation and pressure testing.