Clean Storm J1003G, 2 Inch ID Wire Reinforced Vacuum Motor Hose 50 Ft Box for Carpet Extractors
Description
The Clean Storm J1003G is a 2-inch inner diameter wire reinforced vacuum motor hose supplied in a 50-foot bulk box, engineered for internal vacuum motor connections in commercial carpet cleaning extractors. Built with an embedded helical wire reinforcement, this heavy-duty suction hose resists collapsing and kinking under high negative pressure inside tight machine housings. It serves as a direct replacement for OEM part numbers NM5726, Masterblend 455120, and 67-7984, making it ideal for servicing series or parallel vacuum motor manifolds, recovery tank ports, and rotary hard-surface tools like the SX-15.
Features
- Internal Helical Wire Reinforcement: Integrated steel wire spiral prevents hose collapse and wall deformation under extreme suction loads generated by dual and triple vacuum motor configurations.
- Tight-Radius Flexibility: Engineered to bend smoothly around cramped internal chassis components, motor mounts, and recovery tank bulkheads without kinking or restricting airflow.
- High-Temperature & Chemical Resistance: Constructed from durable industrial-grade polymer compounds that withstand elevated internal cabinet heat and exposure to carpet extraction detergents and defoamers.
- Smooth Bore Interior: Minimizes air turbulence and CFM loss between vacuum motors, maintaining maximum water lift and recovery efficiency.
- 50-Foot Bulk Shop Box: Supplied in a convenient 50-foot continuous length, allowing technicians and repair facilities to cut custom jumper sections to exact OEM lengths with minimal waste.
Applications
- Internal Vacuum Motor Routing: Connecting series and parallel vacuum motor intakes and exhausts inside portable and truckmount carpet cleaning extractors.
- Recovery Tank & Standpipe Plumbing: Linking vacuum motor inlets to recovery tank manifolds and float shut-off assemblies.
- Compatible Equipment & OEM Assemblies: Direct fit replacement for units specifying Clean Storm J1003G, Hydro-Force / Jon-Don NM5726 (including Nautilus MX3-1200 and SX-15 rotary tool repairs), Masterblend 455120, and 67-7984.
- Commercial Restoration & Janitorial Equipment: Suitable for high-suction wet/dry extractors, flood pumpers, and hard-surface cleaning systems requiring 2-inch ID crush-resistant ducting.
Specifications
| Brand |
Clean Storm |
| Manufacturer Part Number |
J1003G |
| Inner Diameter (ID) |
2 Inches (50.8 mm) |
| Total Length |
50 Feet (Bulk Box) |
| Reinforcement Type |
Embedded Helical Steel Wire |
| Connection Type |
Smooth-Cuff / Slip-On Barb Fitment (Non-Threaded) |
| Swivel Mechanics |
Non-Swivel Rigid-Reinforced Flex |
| Pressure Rating |
Full Vacuum / High Negative Pressure Rated (Non-Pressurized Liquid) |
| Operating Temperature |
Engineered for High-Heat Extractor Motor Compartments |
Cross-Reference SKUs
| J1003G |
| Clean Storm J1003G |
| NM5726 |
| NM-5726 |
| Masterblend 455120 |
| 455120 |
| 67-7984 |
| 677984 |
Tips and Additional Information
Cutting & Wire Management: Measure your existing OEM jumper hose carefully before cutting from the 50-foot roll. Use a sharp utility knife to slice the polymer wall, then use heavy-duty diagonal wire cutters to snip the internal steel reinforcement wire cleanly. Tuck or bend the exposed wire tip slightly outward so it cannot puncture the inner liner or obstruct airflow.
Clamping & Sealing: Because this is a non-threaded, non-swivel slip-on motor hose, always secure both ends over barbed motor horns or tank fittings using heavy-duty stainless steel worm-gear hose clamps. Do not use thread sealant or PTFE tape on slip-on vacuum barbs; if an airtight seal is difficult on worn fittings, apply a thin bead of high-temperature RTV silicone around the barb prior to sliding the hose on.
Alignment & Pre-Install Inspection: Route the hose away from sharp sheet-metal edges, hot exhaust manifolds, and moving belts. Ensure there is no axial twisting during installation, as wire-reinforced hoses rely on natural radial flex rather than swivel cuffs. Before closing the machine housing, inspect all clamped joints for air leaks under full vacuum load.
Frequently Asked Questions
Q: Can I use this 2-inch wire reinforced hose as my external floor vacuum hose from the wand to the machine?
No. The Clean Storm J1003G is specifically designed for internal chassis plumbing between vacuum motors and recovery tanks. External floor hoses require crushproof, non-marking flexible cuffs and smoother outer jackets to prevent scuffing carpets and baseboards.
Q: Does this hose come pre-cut into individual motor jumpers or as one continuous piece?
It is supplied as a single 50-foot continuous length inside a bulk box, allowing repair technicians to cut custom lengths for multiple machines or various internal routing paths.
Q: What type of clamps should I use when installing this hose on vacuum motor ports?
Use 2-inch stainless steel worm-gear band clamps or T-bolt clamps. Tighten them firmly just behind the raised ridge of the motor horn or tank barb without over-torquing to the point of crushing plastic fittings.
Warranty & Safety Information
Warranty Coverage: Covered against manufacturing defects in material and workmanship under standard commercial service conditions. Warranty is void if the hose is subjected to incompatible harsh solvents, pinched by improper clamping, punctured during cutting, or used outside its intended vacuum air-routing application.
Pressure, Temperature & Safety Hazards: This hose is rated strictly for vacuum (negative pressure) air and mist transfer; never connect it to high-pressure solution lines or pressurized water pumps. Always disconnect power and unplug the carpet extractor before opening the motor compartment. Wear cut-resistant gloves and eye protection when cutting the embedded steel reinforcement wire to prevent injury from sharp wire ends.
|