HydraMaster 000-038-094 Blower Salsa Heat Exchanger Core – Replaces 000-038-053
Genuine HydraMaster Replacement Heat Exchanger Core
Current Part Number: 000-038-094

Discontinued Part Number: 000-038-053
Product Type: Blower Heat Exchanger Core
Application: HydraMaster Truckmounted Carpet Cleaning Equipment
The HydraMaster 000-038-094 blower heat exchanger core is the updated replacement for the discontinued HydraMaster 000-038-053 heat exchanger. This component is used in the Salsa heat recovery systems found on select HydraMaster truckmounted carpet cleaning machines, including Boxxer 421 and CDS Salsa applications.
The blower heat exchanger recovers thermal energy from the truckmount blower exhaust and transfers that heat into the cleaning solution. This helps the equipment produce heated cleaning water while utilizing energy generated during normal machine operation.
HydraMaster Heat Exchanger Specifications
| Specification |
Description |
| Manufacturer |
HydraMaster |
| Current Part Number |
000-038-094 |
| Previous Part Number |
000-038-053 |
| Product Description |
Blower / Salsa Heat Exchanger Core |
| Heat Exchanger Configuration |
8 Row |
| Core Size |
6 x 8 Inch |
| Fin Configuration |
16 Fin |
| Equipment Type |
Truckmounted Carpet Cleaning Machines |
| Replacement Type |
Updated OEM Replacement Core |
HydraMaster 000-038-094 Replaces 000-038-053
Important Manufacturer Replacement Information: HydraMaster discontinued the original 000-038-053 blower heat exchanger core and replaced it with the updated 000-038-094.
Although the new heat exchanger serves as the replacement for the original component, the plumbing connection orientation has changed.
Original 000-038-053: The plumbing connections were positioned facing the same general direction.
Updated 000-038-094: The plumbing connections are arranged in opposite directions, with one connection facing left and the other facing right.
Because of this design change, installation may require additional plumbing fittings or modifications to the existing water lines.
HydraMaster has recommended using a combination of 45-degree fittings to redirect the plumbing connections as necessary for the specific truckmount installation.
Installation Note: Compare the replacement heat exchanger with the original component before installation. Verify plumbing connections, mounting arrangements, and equipment compatibility.
Compatible HydraMaster Truckmount Equipment
The original 000-038-053 blower heat exchanger was used in select HydraMaster truckmount heating systems, including:
- HydraMaster Boxxer 421 Truckmount
- HydraMaster CDS Salsa Heating Systems
- HydraMaster CDS 4.8 with applicable Salsa heat exchanger configuration
- Other HydraMaster equipment originally equipped with part number 000-038-053
Important: Not every HydraMaster Boxxer or CDS machine uses the same heat exchanger. Always verify the original equipment part number using the manufacturer's parts manual before ordering.
What Does a HydraMaster Blower Heat Exchanger Do?
Truckmounted carpet cleaning equipment generates considerable heat during operation. The blower exhaust is one potential source of recoverable thermal energy.
The HydraMaster Salsa heat recovery system uses a blower heat exchanger to transfer a portion of this energy into the cleaning solution.
This process helps increase cleaning solution temperature without relying exclusively on a separate fuel-fired heating system.
A properly operating heat exchanger contributes to the overall heating performance of the truckmounted extraction system.
Signs Your Truckmount Heat Exchanger May Need Replacement
Possible indications of a damaged or deteriorating blower heat exchanger include:
- Cleaning solution leaking from the heat exchanger
- Visible corrosion or damaged copper tubing
- Reduced heating performance
- Internal restrictions caused by mineral deposits
- Cracked or damaged heat exchanger connections
- Evidence of freeze damage
- Water leakage into the blower exhaust passage
These symptoms may also result from other heating system problems. Proper troubleshooting is recommended before replacing the heat exchanger.
Heat Exchanger Core Only – Reuse Existing Components
This listing is for the replacement heat exchanger core, not a complete Salsa heating system.
Depending on the HydraMaster machine configuration, the original side plates and related mounting components may need to be removed from the existing heat exchanger and reused with the replacement core.
Inspect the original mounting components, fittings, and connections before installation. Additional parts may be required depending on equipment condition and configuration.
HydraMaster Heat Exchanger Cross Reference Numbers
- 000-038-094 – Current replacement heat exchanger core
- 000038094 – Part number without hyphens
- 000-038-053 – Discontinued original heat exchanger core
- 000038053 – Original part number without hyphens
Customers searching for the discontinued HydraMaster 000-038-053 blower heat exchanger should order the updated replacement part number 000-038-094, subject to equipment compatibility verification.
Frequently Asked Questions
Does HydraMaster 000-038-094 replace 000-038-053?
Yes. HydraMaster 000-038-094 is the updated replacement for the discontinued 000-038-053 blower heat exchanger core.
Will the new heat exchanger install exactly like the original?
Not necessarily. The updated heat exchanger has a different plumbing port orientation. Additional fittings may be required to connect the replacement core to the existing truckmount plumbing.
Does this fit the HydraMaster Boxxer 421?
The replacement core is listed for applicable HydraMaster Boxxer 421 blower heat exchanger applications. Verify that the machine originally used part number 000-038-053 before ordering.
Will this work on a HydraMaster CDS Salsa system?
Yes, for applicable CDS Salsa systems originally equipped with the 000-038-053 blower heat exchanger. Confirm the original part number and plumbing configuration before purchasing.
Are the Salsa housing and side plates included?
This product is sold as a replacement heat exchanger core. Existing side plates and other components may need to be transferred from the original assembly. Do not assume the complete heating assembly is included.
Can mineral scale affect heat exchanger performance?
Yes. Mineral deposits can accumulate inside water passages and restrict flow. Scale buildup can reduce heat transfer efficiency and contribute to heating system problems.
Use appropriate water treatment and manufacturer-approved maintenance procedures to help minimize mineral deposits inside truckmount heating components.
Ordering Information
Order Part Number: 000-038-094
Replaces: 000-038-053
Manufacturer: HydraMaster
Product: Blower Salsa Heat Exchanger Core
Steam-Brite supplies replacement parts for HydraMaster truckmounted carpet cleaning equipment, including heat exchangers, pumps, blowers, heating system components, fittings, and truckmount repair parts.
Special Order Notice: HydraMaster replacement parts may be subject to manufacturer availability, lead times, price changes, and special-order restrictions. Please review the current product ordering terms before purchasing.
Image Disclaimer: Product photographs and illustrations are for identification purposes. The current replacement may differ in appearance or connection orientation from the original discontinued component. Verify the manufacturer's part number before ordering.
Number 1 in Image
R 6X8 16 FIN
*** 2024 update, this part has been replaced by updated p/n [000-038-094]
*** Note that this means it will arrive with both ports no longer facing the same way, as one will face left, and one will face right, so the factory recommends using a double 45 degree angle fittings to redirect the flow as needed.
Optional
 |
Magnetic Clamp-On Water Softener Descaler for Truckmount & Portable Carpet Cleaning Machines 20260425
- Helps prevent scale buildup in pipes, coils, heaters, and carpet cleaning heat exchangers
- Reduces or eliminates routine monthly descaling in many applications
- Clamp-on installation — no cutting, plumbing, salt, chemicals, or cartridge replacement
- Maintenance-free design — no salt, resin, plastic pellets, filters, or media to flush
- Improves heat transfer efficiency by helping keep mineral buildup off heater surfaces
- May improve water flow / GPM by helping reduce mineral restriction over time
- Only 4 inches long for installation in tight areas on portable and truckmount equipment
- Longer Equipment lifespan
|
All HYDRAMASTER ORDERS ARE FINAL, NON-CANCELLABLE, NO REFUNDS!
|