HydraMaster 000-038-097 Stainless Steel Blower Heat Exchanger Core - 10 Row, 8 x 8, 9 Fin
Genuine HydraMaster OEM Replacement Part Number: 000-038-097
The HydraMaster 000-038-097 is a stainless steel heat exchanger core designed for use in select HydraMaster truckmounted carpet cleaning machines. This 10-row, 8 x 8, 9-fin heat exchanger is used in applications involving the recovery of heat from the blower and engine exhaust systems.
The heat exchanger transfers recovered exhaust heat into the cleaning solution, helping the truckmount produce the hot water needed for professional carpet cleaning, upholstery cleaning, and hard surface cleaning.
Product Specifications
- Manufacturer: HydraMaster
- OEM Part Number: 000-038-097
- Product: Heat Exchanger Core
- Construction: Stainless Steel
- Core Configuration: 10 Row
- Nominal Core Size: 8 x 8 Inches
- Fin Specification: 9 Fin
- Application: Truckmount Blower / Engine Exhaust Heat Recovery System
- Condition: New OEM Replacement Part
HydraMaster Truckmount Applications
This heat exchanger core may be used in certain configurations of the following HydraMaster truckmounted carpet cleaning machines. Consult the factory parts diagrams to confirm the correct replacement part number before ordering.
- HydraMaster Titan 575 - Blower Heat Exchanger Assembly, Page 9-34
- HydraMaster Titan 625 - Blower Heat Exchanger Assembly, Page 9-16
- HydraMaster Titan 875 - Blower Heat Exchanger Assembly, Page 9-28
- HydraMaster Boxxer XL - Blower Heat Exchanger Assembly, Page 9-17
IMPORTANT COMPATIBILITY NOTICE: HydraMaster has manufactured different heat exchanger configurations across its truckmount product lines. Not every Titan or Boxxer model uses the same heat exchanger core. Verify OEM part number 000-038-097 against the parts diagram for your exact machine model and serial number before ordering.
Common Reasons for Heat Exchanger Replacement
- Internal water leakage or damaged heat exchanger passages
- Freeze damage caused by water remaining inside the core
- Corrosion or deterioration of the existing heat exchanger
- Mineral deposits restricting water flow
- Reduced heating performance caused by internal buildup
- Physical damage to the heat exchanger assembly
Stainless Steel Heat Exchanger Construction
Stainless steel construction provides corrosion resistance and durability in the demanding operating environment of a professional truckmounted carpet cleaning machine.
The heat exchanger is designed to recover heat that would otherwise be discharged through the machine's exhaust system. This recovered thermal energy helps heat the cleaning solution without requiring a separate fuel-fired water heater.
Important Ordering and Installation Information
CORE ONLY: This listing is for HydraMaster OEM heat exchanger core 000-038-097. Outer collars, housings, mounting hardware, gaskets, and other accessories are not included unless specifically supplied by the manufacturer as part of this part number.
PHOTO DISCLAIMER: Product photographs are provided for reference. Orders are filled according to the HydraMaster OEM part number rather than the exact appearance of the photograph. The manufacturer reserves the right to make production changes without prior notice.
Before ordering, compare the existing heat exchanger part number and the factory schematic. If your original core has a different part number, confirm interchangeability with HydraMaster before purchasing.
Installation should be performed by a qualified technician familiar with truckmounted carpet cleaning equipment. Inspect associated hoses, fittings, gaskets, and mounting components during replacement.
Related HydraMaster Heat Exchanger Parts
HydraMaster manufactures several different heat exchanger cores for its truckmount equipment. Other part numbers include:
- 000-038-001 - Original Copper/Aluminum Blower Heat Exchanger Core
- 000-038-096 - Stainless Steel Blower / Engine Heat Exchanger Core
- 000-038-097 - Stainless Steel 10-Row, 8 x 8, 9-Fin Heat Exchanger Core
Note: These part numbers are not necessarily interchangeable. Verify the correct replacement using your machine's factory parts diagram.
HydraMaster Special Order Policy
ALL HYDRAMASTER ORDERS ARE FINAL, NON-CANCELLABLE, AND NON-REFUNDABLE.
Please verify the correct OEM part number and equipment compatibility before placing your order.
Steam-Brite Inc. - Genuine HydraMaster Replacement Parts and Truckmount Cleaning Equipment.
- Titan 575 — blower heat exchanger, page 9-34. Manual
- Titan 625 — blower heat exchanger, page 9-16. Manual
- Titan 875 — blower heat exchanger, page 9-28. Manual
- Boxxer XL — blower heat exchanger, page 9-17. Manual
Core only in photo, will not include the outer collars / Item filled by part number and not this photo on this webpage.
Optional
 |
Magnetic Clamp-On Water Softener Descaler for Truckmount & Portable Carpet Cleaning Machines 20260425
- Helps prevent scale buildup in pipes, coils, heaters, and carpet cleaning heat exchangers
- Reduces or eliminates routine monthly descaling in many applications
- Clamp-on installation — no cutting, plumbing, salt, chemicals, or cartridge replacement
- Maintenance-free design — no salt, resin, plastic pellets, filters, or media to flush
- Improves heat transfer efficiency by helping keep mineral buildup off heater surfaces
- May improve water flow / GPM by helping reduce mineral restriction over time
- Only 4 inches long for installation in tight areas on portable and truckmount equipment
- Longer Equipment lifespan
|
|