Aquatec 58-ELK-120 Water Pump – 120 PSI, 115 Volt, 1.3 GPM
Professional replacement demand pump for portable carpet extractors, auto-detailing machines, upholstery cleaning equipment and other low-flow water-delivery applications. Commonly cross-referenced to Mytee C305, EDIC G13761, AP120 and 58-FLC-120.
Important Before Ordering
Confirm that your existing pump is rated for 115 volts AC, uses 3/8-inch female pipe-thread ports, and is designed for approximately 100 to 120 PSI. Compare the voltage, port orientation, mounting dimensions, wiring and chemical compatibility with your original pump.
Product Overview

The Aquatec 58-ELK-120 is a compact, three-chamber diaphragm pump designed to provide water pressure on demand. When the cleaning tool is opened, system pressure drops and the pump turns on. When the tool is released and pressure reaches the switch setting, the pump automatically turns off.
Its internal bypass design helps manage low-flow applications such as upholstery tools and small spray tips. The totally enclosed motor also helps protect internal components from the moisture and dust commonly found inside portable carpet-cleaning equipment.
Key Features
- 120 PSI maximum pressure rating
- 115-volt AC motor for standard commercial extractor applications
- Approximately 1.3 GPM open-flow capacity
- Three-chamber diaphragm pump design
- Automatic demand pressure switch
- Internal bypass helps reduce rapid cycling during low-flow operation
- Self-priming design when properly installed and supplied with water
- Can tolerate brief dry operation, but should not be intentionally operated dry for extended periods
- Totally enclosed, non-ventilated permanent-magnet motor
- Compact replacement for many Shurflo, Flojet, Mytee and extractor-style pumps
- Made for professional carpet-cleaning and water-transfer equipment
Specifications
| Manufacturer |
Aquatec |
| Primary Part Number |
58-ELK-120 / 58ELK120 |
| Pump Type |
Demand-style, three-chamber diaphragm pump |
| Voltage |
115 VAC, 60 Hz |
| Maximum Pressure |
120 PSI |
| Open Flow |
Approximately 1.3 to 1.35 GPM |
| Ports |
3/8-inch female pipe thread inlet and outlet |
| Motor |
Permanent magnet, totally enclosed, non-ventilated |
| Operating Style |
Pressure-switched with internal bypass |
| Typical Duty |
Intermittent commercial operation |
| Maximum Liquid Temperature |
Up to approximately 170°F, subject to the exact pump configuration and label |
What You Receive
- One Aquatec 58-ELK-120 complete pump and motor assembly
- Factory-installed demand switch and internal bypass assembly
Not included unless specifically shown: plumbing fittings, hoses, quick disconnects, mounting hardware, electrical connectors, power cord or installation labor. Transfer reusable fittings from the original pump only when they are clean, undamaged and compatible.
Common Part-Number Cross References
- Aquatec 58-ELK-120
- Aquatec 58ELK120
- Aquatec 58-FLC-120
- Aquatec 58-MGD-120
- Mytee C305
- Mytee MYC305
- Mytee 58-MTY-C305
- EDIC G13761
- AP120
- Timbuktoo Manufacturing part number: TMI 8665202141
- A120-115
- CAP120
- Powr-Flite AQ120
- Legend Brands 111500
- Esteam 511-100
- KleenRite SL-22.36
- Mosquito 500-0006
- Pullman-Holt Boss B003120
- Ninja 8.620-105.0
Cross-reference notice: A matching reference number does not guarantee that every fitting, connector, mounting bracket or port direction will be identical. Manufacturers can change components during a machine’s production life. Always compare the pump being removed with the photos and specifications before ordering.
Common Machine Applications
Depending on the machine’s production date and original configuration, this pump may be used in or adapted to selected equipment from Mytee, EDIC, Powr-Flite, Windsor, Tennant, Nobles, Clarke, Alto, Castex, Esteam, Ninja, Sandia and other portable-extractor manufacturers.
Common Mytee applications include selected versions of:
- Mytee 8070 Lite
- Mytee HP60 Spyder
- Mytee HP120 Grand Prix
- Mytee 2002CS Contractor’s Special
- Mytee automotive detailing extractors using the C305 pump
Machine compatibility is dependent upon the original voltage, pressure, plumbing, switch type, port arrangement and mounting space. Order by specifications and part number rather than by machine name alone.
Installation Notes
- Disconnect the machine from electrical power before opening or servicing it.
- Drain or empty the solution tank.
- Photograph the original plumbing, wiring and pump orientation before disassembly.
- Mark the inlet, outlet and electrical wires before removing the old pump.
- Install the replacement with the flow arrow pointing in the correct direction.
- Use thread sealant that is compatible with the pumped solution.
- Do not overtighten fittings into the plastic pump head.
- Confirm that hoses are not kinked and that the inlet filter is clean.
- Fill the solution tank with clean water and prime the pump before checking operating pressure.
- Inspect every connection for leaks before returning the machine to service.
Electrical Safety: Installation and testing should be performed by a qualified service technician. Disconnect the machine from the wall outlet before servicing. Do not rely only on the machine’s switches to remove electrical power.
New Pump Runs but Does Not Move Water?
A replacement pump may run normally but fail to move water until trapped air is removed from the inlet line and pump head. This is commonly mistaken for a defective pump.
Basic priming procedure
- Place clean water in the machine’s solution tank.
- Confirm that the tank outlet, inlet hose and filter are unobstructed.
- Open the cleaning tool or remove the restriction from the pump outlet.
- Turn on the pump and allow water time to reach the pump head.
- If necessary, apply gentle suction at the solution outlet to pull water through the inlet hose and pump.
- Once solid water flow is established, reconnect the tool and test the system.
Never operate the pump for an extended period without water. Also check for a closed valve, clogged inlet screen, reversed plumbing, air leak on the suction side or a stuck downstream check valve.
Pump Pulses On and Off While Spraying
Pulsation does not automatically mean the pump is defective. A demand pump can build pressure faster than a very small spray tip releases water. The pressure switch then turns the pump off; continued spraying lowers the pressure and turns it back on.
Before replacing the pump, inspect the following:
- Spray tip or jet is too small
- Jet is partially clogged
- Solution filter is restricted
- Hose is kinked or internally damaged
- Tool valve is not opening completely
- Pressure-switch adjustment does not match the application
- Internal bypass requires adjustment or service
Pressure-switch adjustments should be made in very small increments by a qualified technician. Excessive adjustment can cause leaks, motor overheating, damaged hoses or excessive system pressure.
Chemical and Freeze-Damage Warning
This pump is intended primarily for water and properly diluted carpet-cleaning solutions. Strong solvents, concentrated degreasers, acids, caustics, incompatible oxidizers and other aggressive chemicals can damage the diaphragm, valves, seals and pump housing.
- Never allow cleaning chemical to remain inside the pump during storage.
- Flush the pump and solution system with clean water after chemical use.
- Protect the machine from freezing.
- Freeze damage, chemical damage and installation damage are not manufacturing defects.
Frequently Asked Questions
Is this an OEM Mytee C305 pump?
This Aquatec pump is commonly cross-referenced and used as the pump assembly associated with Mytee part number C305. Confirm the voltage, pressure, ports and physical configuration of your original pump before ordering.
Can it replace a 100 PSI pump?
It may replace many 100 PSI extractor pumps when the voltage, port size, flow requirements, mounting space and downstream components are compatible. The machine’s hoses, heater, pressure-relief valve and fittings must be rated for the replacement pressure.
Can I install it in place of a 12-volt pump?
No. This listing is for a 115-volt AC pump. Never connect it to a 12-volt DC system.
Does the pump include plumbing fittings?
No fittings are included unless specifically pictured or stated in the “What You Receive” section. Existing fittings are commonly transferred from the original pump.
Why does the pump run without spraying water?
The most common causes are loss of prime, an empty tank, a blocked inlet screen, an air leak, reversed plumbing, a clogged jet or a stuck downstream check valve.
Can electrical pumps be returned after installation?
Electrical components are generally not returnable after installation, wiring, exposure to water or operation. Verify compatibility before opening, modifying or installing the pump.
Warranty and Return Notice
Electrical parts should be inspected and compared with the original part before installation. Once a pump has been wired, installed, filled with liquid or operated, it is considered used. Manufacturing-defect claims are handled under the applicable manufacturer’s parts warranty.
Warranty coverage does not normally include labor, diagnostic time, removal, installation, shipping, freeze damage, chemical damage, clogged plumbing, improper voltage, incorrect wiring, pressure-switch misadjustment or damage caused by incompatible fittings.